DP-V2411, Firmware Version 1.3.2

    15-ต.ค.-2020
    0400609602

    ดาวน์โหลด

    ฉันได้อ่านและทำความเข้าใจข้อจำกัดความรับผิดชอบด้านล่าง
    และต้องการดาวน์โหลดซอฟต์แวร์ที่กำหนด

    ระบบปฏิบัติการ

    • Windows 10 (x64)
    • Windows 10
    • Windows 8.1 (x64)
    • Windows 8.1
    • Windows 8 (x64)
    • Windows 8
    • Windows 7 (x64)
    • Windows 7
    • Windows Vista (x64)
    • Windows Vista
    • Windows XP
    • macOS 11
    • macOS 10.15
    • macOS 10.14
    • macOS 10.13
    • macOS v10.12
    • OS X v10.11
    • OS X v10.10
    • OS X v10.9
    • Mac OS X v10.8
    • Mac OS X v10.7
    • Mac OS X v10.6
    • Mac OS X v10.5

    รายละเอียด

    Details of changes made to the firmware
    This firmware (Version 1.3.2) incorporates the following fix:

    1. Fixes a malfunction that may prevent the use of the on-screen tally display function utilizing the TSL UMD protocol.

    Firmware Version 1.3.2 is for the DP-V2411 Reference Display running Firmware Version 1.3.1 or earlier. If the Reference Display's firmware is already version 1.3.2, it is not necessary to update the firmware.

    Please note that Firmware Version 1.3.2 includes all the enhancements available in Firmware Version 1.3. The details of Firmware Version 1.3 are as follows.

    1. The black luminance has been improved to 0.001 cd/m2 *1/2 in boost mode and local dimming.
    2. LUT files in .cube format can now be directly imported to the display unit.
    3. 1D-LUTs can now be imported to User LUT. The video signal range can also now be converted before or after User LUT (1D-LUT / 3D-LUT) processing.
    4. When outputting Canon Log video from a Cinema EOS camera*3 over SDI or HDMI, the display unit can now auto detect and display the color range (full or limited) matching the output video range (full range or narrow range).
    5. Added two LUTs to "CDL/User LUT" that convert video taken with RED Digital Cinema cameras to HDR (PQ) and SDR.
    6. Added a function to "Pixel Value Check" that indicates the xy chromaticity values of a specified pixel as well as its coordinate position on the chromaticity diagram.*4
    7. Added "Peak Range" to "Range Check" that highlights high-luminance range areas set with the normal "Over Range" setting.
    8. Errors detected by "Signal Monitoring" can now be exported as a log to USB memory sticks or other external memory devices. The error log is now preserved even after a power down-power up cycle.
    9. Changed the range of settings for the area size (width and height) and the area display position (horizontal and vertical) for the "Safety Zone Marker". Also added "Box (Mask)" to the area shapes.
    10. Added "Area Marker 2". It is now possible to set two area markers.
    11. Added 80% (UHD) – 95% (UHD) to the "Grid Marker" Interval setting.
    12. Added settings to adjust the channel order and display position on the "Audio Level Meter".
    13. It is now possible to select and display 16:9 and 4:3 to match the aspect ratio when displaying SD-SDI signal video. Auto-detection and display with Payload ID is now also possible.
    14. The unit can now automatically detect and switch the display when the input signal switches between SD-SDI and HD-SDI.
    15. Added "Marker 1/2/3", "Monochrome", "Blue Only", "Red Off", "Green Off", and "Blue Off" to the functions that can be saved under each GPI pin under "Remote(GPI)".
    16. Added 10% and 5% to the display scaling options for HDR / SDR ratio graphs on the "Frame Luminance Monitor".
    17. Improved web browser usability, including moving the position of the pixel value checker by click or touch on the View window during remote operation via Wi-Fi or LAN and allowing direct entry of values for the adjustment bar on the Control window.
    18. Added a setting to keep the unit button names continuously lit.
    19. Changed the behavior when using auto system gamma for Hybrid Log-Gamma (HLG).
    20. Added a power-save function.
    21. Made other usability and display improvements.

    *1 Luminance values stated here are standard values at the time of factory shipment and are not guaranteed performance values.
    *2 Applicable only when the full screen is displayed in black.
    *3 Cinema EOS camera models that permit Canon Log range selection
    C500 Mark II / C300 Mark III (both SDI/HDMI are supported)
    C700 / C700 GS / C700 FF (User LUT settings and SDI only)
    (Current as of the end of May 2020)
    *4 Only for the BT.2020 color gamut and a 1.0, 2.2, 2.35, 2.4, 2.6, PQ, or HLG (excluding HLG RGB) gamma curve.

    Preparations for updating the firmware
    It is recommended that current settings are exported before attempting to update the firmware. Once the firmware is updated, settings can be imported back to the display.
    The downloaded folder contains the new firmware. (Filename: "update_dpv2411.rom", file size: 23,637,722 bytes) It also contains the firmware update procedure document (multilingual PDF file in following languages: Japanese, English, French, German and Chinese (simplified characters). Before proceeding to update the firmware, please read the firmware update procedure document.

    Software Used in This Product
    Software installed with this product includes software modules from Canon or third parties.

    Software Developed by Canon and Free Software
    Software developed or created by Canon and accompanying document is protected by copyright law, terms of an international convention and any other governing laws.
    This product uses software modules under copyright by third parties and distributed as free software. Some of these software modules are subject to the GNU General Public License v2 (GPL), GNU Lesser General Public License v2.1 (LGPL) or any other license.

    ความต้องการของระบบ

    The following items are required to perform the firmware update:
    1. Video Display unit
    2. Personal computer
    3. USB memory (FAT16 or FAT32)
    4. Firmware (The downloaded file)

    ข้อมูลไฟล์

    1. ชื่อไฟล์: DP-V2411-V132.zip
    2. เวอร์ชันไฟล์: 1.3.2
    3. ประเภทไฟล์: zip
    4. ขนาดไฟล์: 26780KB

    ข้อจำกัดความรับผิดชอบ

    ซอฟต์แวร์ โปรแกรม (รวมถึงแต่ไม่จำกัดเพียงไดรเวอร์) ไฟล์ เอกสาร คู่มือ คำแนะนำ หรือเนื้อหาอื่นใด (รวมเรียกว่า "เนื้อหา") ทั้งหมดที่มีอยู่ในเว็บไซต์นี้อยู่บนพื้นฐาน "ตามสภาพที่เป็นอยู่

    บริษัท แคนนอน มาร์เก็ตติ้ง (ไทยแลนด์) จำกัด และบริษัทในเครือ ("แคนนอน") ขอสงวนสิทธิ์ไม่รับประกันใดๆ เกี่ยวกับเนื้อหาและขอปฏิเสธการรับประกันทั้งหมดโดยชัดแจ้งหรือโดยนัย (รวมถึงแต่ไม่จำกัดเพียงการรับประกันโดยนัยของความสามารถในการซื้อขาย ความเหมาะสมสำหรับวัตถุประสงค์เฉพาะและการไม่ละเมิด ) และไม่รับผิดชอบต่อการปรับปรุง การแก้ไข หรือการสนับสนุนเนื้อหา

    แคนนอนของสงวนสิทธิ์ ในชื่อ ความเป็นเจ้าของ และสิทธิ์ในทรัพย์สินทางปัญญาที่เกี่ยวข้องทั้งหมดในเนื้อหา คุณสามารถดาวน์โหลดและใช้เนื้อหาเฉพาะเพื่อวัตถุประสงค์ส่วนตัวที่มิได้เป็นการใช้งานเชิงพาณิชภายใต้ความเสี่ยงของคุณเอง แคนนอนจะไม่รับผิดชอบต่อความเสียหายใดก็ตามที่เกี่ยวข้องกับเนื้อหา (รวมถึงแต่ไม่จำกัดเพียงค่าเสียหายทางอ้อม ค่าเสียหายที่เป็นผลสืบเนื่อง ค่าเสียหายเพื่อเป็นเยี่ยงอย่างหรือค่าเสียหายที่ไม่ได้เกิดขึ้นทันที หรือไม่ได้คาดหมายไว้แต่ต้น)

    คุณไม่ได้รับอนุญาตให้ทำการแจกจ่าย มอบหมาย อนุญาต ขาย ให้เช่า ออกอากาศ ส่ง เผยแพร่ หรือโอนเนื้อหาไปยังบุคคลอื่น นอกจากนี้คุณจะต้องไม่ (และไม่อนุญาตให้ผู้อื่น) ทำการผลิตซ้ำ ดัดแปลง เปลี่ยนรูปแบบ ถอดประกอบ ถอดรหัส หรือทำวิศวกรรมย้อนกลับ หรือสร้างงานลอกเลียนแบบจากเนื้อหาทั้งหมดหรือบางส่วน

    คุณตกลงที่จะไม่ส่งหรือนำเนื้อหาจากประเทศ / ภูมิภาคที่คุณได้รับไปยังประเทศ / ภูมิภาคอื่น ๆ โดยไม่ได้รับอนุญาตจากรัฐบาลที่เกี่ยวข้อง (ในกรณีที่กฎหมายกำหนดให้ต้องทำเช่นนั้น) และ / หรือการละเมิดกฎหมาย ข้อจำกัด หรือข้อบังคับใด ๆ

    ในการดาวน์โหลดเนื้อหา คุณตกลงที่จะผูกพันตามกฎหมายและระเบียบข้อบังคับทั้งหมดข้างต้นที่บังคับใช้ที่เกี่ยวข้องกับการดาวน์โหลดและการใช้เนื้อหาของคุณ